
Transcription
Edition: 04/06/2021AXISH1200/DS H1400 H1600/DS H1600XXL/DSH1200VLG/D H12003V epi950Installation & User guide1. Specifications2. preliminary INSTALL GUIDE3. Outdoor air kit4. COMPONENTS LIST5.0 INBUILT AGAINST COMBUSTIBLE WALL5.1 MASONRY BRICK INSTALLATION5.2 HEBEL INSTALLATION6. INBUILT INTO ISLAND WALLNO COMBUSTIBLE SURROUNDINGS7. Appliance details8. OPERATION & MAINTENANCE9. TEST RESULTS9. WarrantyNOTICE TO INSTALLER:These instructions must be left with the owner, who should retain for future use.1
Compliance plate and serial number.The instructions in this manual are recommendations only, the distributor and manufacturer bears no liability to the interpretation of these instructions.Please ensure to download the latest version of this manual from our website: ll rights retained Copyright 2021 Sculpt Fireplaces Collection2
Congratulations!Thank you for choosing Sculpt Fireplaces as your heater of choice.Your fireplace is the result of careful design, artisan engineering and safety tests.If it is properly installed, used and maintained, you may be sure that you will have an outstandingheating feature in your home for years to come.We advise you to read through this guide in order to become acquainted with the installationmethods specific to your fireplace.It is recommended that this fireplace be installed by a qualified and licensed trades professional.You will find in this guide the answers to most of your questions, should you require furtherassistance we recommend you contact your retailer.Before igniting your fireplace for the first time, please carefully read this manual.Follow @sculptfireplacecollection on Instagram, SculptFireplaceCollection on Facebook and besure to post your latest masterpiece installed with the hashtag #sculptfires.We hope we’ve helped make you the envy of your friends this winter and for years to come.From all of us,Sculpt Fireplace Collection3
This installation manual at times is updated, to view the latest manual please refer to thesupport section of the Sculpt Fireplace Collection website.All fireplaces in this manual conform to Australian and New Zealand standardsAS/NZS 2918:2018 domestic solid fuel burning appliances & AS/NZS 4012/4013(2014).IMPORTANTHeating capacity of the following appliances are a guide only and refers to areas with 2.4m ceilingsand 6 or more star rated buildings. Heating output may vary depending on factors such as buildingcharacteristics, quality of insulation, type of firewood used and climate zone.All dimensions shown are approximate. Check all dimensions accurately prior to installation. In line withour policy of continuous improvement, we reserve the right to alter specifications without notice.All units comply and MUST be installed to Australian & New Zealand Standard AS/NZS 2918:2018.When in use some parts may become hot. A suitable fire guard is recommended where very young,elderly or infirm are concerned.The instructions in this manual are recommendations only, the distributor and manufacturer bears no liability to the interpretation of these instructions. Copyright 2021 Sculpt Fireplace Collection (ACN: 169053883)4
1. SPECIFICATIONSaxis H1200Solid steel firebox with 60mm thick fire bricks30kWUp to 200m2*Clean frame-less design(trim options available)Secure swing & lift door5.4m250mm, 300mm, 350mmTwo ducts and two registersRecommended for well insulated homes10 year fire brick & 5 year firebox warranty**380kgAdjustable 180mm-600mmMin 500mm in front of any part of fireplace, 250mm on eitherside & 100mm thick618mmmaterialKW outputHeating capacity*facaceGlass doorminimum flue heightflue sizesincludes hot air kitoutside air kitwarrantyweightLegs**hearth 1mm180mm*** Heating capacity of the following appliances are a guide only and refers to areas with 2.4m ceilingsand 6 or more star rated buildings. Heating output may vary depending on factors such as buildingcharacteristics, quality of insulation, type of firewood used and climate zone.** See warranty pg. 54 of the manual5
1. SPECIFICATIONSaxis H1200DSmaterialKW outputHeating capacity*facaceGlass doorminimum flue heightflue sizesincludes hot air kitoutside air kitwarrantyweightLegs**hearth dimensions*Solid steel firebox with 60mm thick fire bricks30kWUp to 200m2*Clean frame-less design(trim options available)Secure swing & lift door5.4m250mm, 300mm, 350mmTwo ducts and two registersRecommended for well insulated homes10 year fire brick & 5 year firebox warranty**380kgAdjustable 180mm-600mmMin 500mm in front of any part of fireplace, 250mm on eitherside & 75mm 923mm171mm180mm***Heating capacity of the following appliances are a guide only and refers to areas with 2.4m ceilingsand 6 or more star rated buildings. Heating output may vary depending on factors such as buildingcharacteristics, quality of insulation, type of firewood used and climate zone.**See warranty pg. 54 of the manual6
1. SPECIFICATIONSaxis H1400Solid steel firebox with 60mm thick fire bricks32.5kWUp to 280-320m2*Clean frame-less design(trim options available)Secure swing & lift door5.4m300mm, 350mm, 400mmTwo ducts and two registersRecommended for well insulated homes10 year fire brick & 5 year firebox warranty**400kgAdjustable 180mm-600mmMin 500mm in front of any part of fireplace, 250mm on eitherside & 100mm thickmaterialKW outputHeating capacity*facaceGlass doorminimum flue heightflue sizesincludes hot air kitoutside air kitwarrantyweightLEGS**hearth 82mm1108mm170mm180mm**624mm*Heating capacity of the following appliances are a guide only and refers to areas with 2.4m ceilingsand 6 or more star rated buildings. Heating output may vary depending on factors such as buildingcharacteristics, quality of insulation, type of firewood used and climate zone.**See warranty pg. 54 of the manual7
1. SPECIFICATIONSaxis H1600materialKW outputHeating capacity*facaceGlass doorminimum flue heightflue sizesincludes hot air kitoutside air kitwarrantyweightLeGs**hearth dimensions*Solid steel firebox with 60mm thick fire bricks35kWUp to 300-350m2*Clean frame-less design (trim options available)Secure swing & lift door5.4m300mm, 350mm, 400mmTwo ducts and two registersRecommended for well insulated homes10 year fire brick & 5 year firebox warranty**460kgAdjustable 180mm-600mmMin 500mm in front of any part of fireplace, 250mm on eitherside & 100mm 0mm180mm***Heating capacity of the following appliances are a guide only and refers to areas with 2.4m ceilingsand 6 or more star rated buildings. Heating output may vary depending on factors such as buildingcharacteristics, quality of insulation, type of firewood used and climate zone.**See warranty pg. 54 of the manual8
1. SPECIFICATIONSaxis H1600DS620mm110mm1300mm450mm491mm1330mm555mmSolid steel firebox with 60mm thick fire bricks25kWUp to 250m2*Clean frame-less design (trim options available)Secure swing & lift door5.4m300mm, 350mm, 400mmTwo ducts and two registersRecommended for well insulated homes10 year fire brick & 5 year firebox warranty**460kgAdjustable 180mm-600mmMin 500mm in front of any part of fireplace, 250mm on eitherside & 75mm thick548mm491mmmaterialKW outputHeating capacity*facaceGlass doorminimum flue heightflue sizesincludes hot air kitoutside air kitwarrantyweightLegs**hearth dimensions*481mm170mm**180mm***Heating capacity of the following appliances are a guide only and refers to areas with 2.4m ceilingsand 6 or more star rated buildings. Heating output may vary depending on factors such as buildingcharacteristics, quality of insulation, type of firewood used and climate zone.**See warranty pg. 54 of the manual9
1. SPECIFICATIONSaxis 9mmSolid steel firebox with 60mm thick fire bricks40kW Up to 350-400m2*Clean frame-less design (trim options available)Secure swing & lift door5.4m300mm, 350mm, 400mmTwo ducts and two registersRecommended for well insulated homes10 year fire brick & 5 year firebox warranty**530kgAdjustable 180mm-600mmMin 500mm in front of any part of fireplace, 250mm on eitherside & 100mm thick504mmmaterialKW outputHeating capacity*facaceGlass doorminimum flue heightflue sizesincludes hot air kitoutside air kitwarrantyweightLEGS**hearth dimensions*200mm180mm***Heating capacity of the following appliances are a guide only and refers to areas with 2.4m ceilingsand 6 or more star rated buildings. Heating output may vary depending on factors such as buildingcharacteristics, quality of insulation, type of firewood used and climate zone.**See warranty pg. 54 of the manual10
1. SPECIFICATIONSaxis H1600XXL DSSolid steel firebox with 60mm thick fire bricks30kWUp to 300m2*Clean frame-less design (trim options available)Secure swing & swing door5.4m300mm, 350mm, 400mmTwo ducts and two registersRecommended for well insulated homes10 year fire brick & 5 year firebox warranty**530kgAdjustable 180mm-600mmMin 500mm in front of any part of fireplace, 250mm on eitherside & 75mm thick579mmmaterialKW outputHeating capacity*facaceGlass doorminimum flue heightflue sizesincludes hot air kitoutside air kitwarrantyweightLeGS**hearth 1712mm200mm180mm***Heating capacity of the following appliances are a guide only and refers to areas with 2.4m ceilingsand 6 or more star rated buildings. Heating output may vary depending on factors such as buildingcharacteristics, quality of insulation, type of firewood used and climate zone.**See warranty pg. 54 of the manual11
1. SPECIFICATIONSaxis H1200 3VSolid steel firebox with 60mm thick fire bricks20kWUp to 200m2*Clean frame-less design (trim options available)Secure swing & lift door5.4m250mm, 300mm, 350mmTwo ducts and two registersRecommended for well insulated homes10 year fire brick & 5 year firebox warranty**380kgAdjustable 180mm-600mmMin 500mm in front of any part of fireplace, 250mm on eitherside & 75mm KW outputHeating capacity*facaceGlass doorminimum flue heightflue sizesincludes hot air kitoutside air kitwarrantyweightLegs**hearth eating capacity of the following appliances are a guide only and refers to areas with 2.4m ceilingsand 6 or more star rated buildings. Heating output may vary depending on factors such as buildingcharacteristics, quality of insulation, type of firewood used and climate zone.**See warranty pg. 54 of the manual12
1. SPECIFICATIONSaxis epi 950638mmmaterialKW outputHeating capacity*facaceGlass doorminimum flue heightflue sizesincludes hot air kitoutside air kitwarrantyweightLEGS**hearth dimensions*Solid steel firebox with 60mm thick fire bricks20kWUp to 150-200m2*Clean frame-less design (trim options available)Secure swing & lift door5.4m280mm, 330mm, 380mmTwo ducts and two registersRecommended for well insulated homes10 year fire brick & 5 year firebox warranty**330kgAdjustable 180mm-600mmMin 500mm in front of any part of fireplace, 250mm on eitherside & 75mm m**530mm800mm565mm1010mm*Heating capacity of the following appliances are a guide only and refers to areas with 2.4m ceilingsand 6 or more star rated buildings. Heating output may vary depending on factors such as buildingcharacteristics, quality of insulation, type of firewood used and climate zone.**See warranty pg. 54 of the manual13
axis H1200 VLG/DSolid steel firebox with 60mm thick fire bricks20kWUp to 200m2*Clean frame-less design (trim options available)Secure swing & lift door5.4m250mm, 300mm, 350mmTwo ducts and two registersRecommended for well insulated homes10 year fire brick & 5 year firebox warranty**380kgAdjustable 180mm-600mmMin 500mm in front of any part of fireplace, 250mm on eitherside & 75mm thickmaterialKW outputHeating capacity*facadeGlass doorminimum flue heightflue sizesincludes hot air kitoutside air kitwarrantyweightLEGS**hearth mm1082mm642mm167mm180mm***Heating capacity of the following appliances are a guide only and refers to areas with 2.4m ceilingsand 6 or more star rated buildings. Heating output may vary depending on factors such as buildingcharacteristics, quality of insulation, type of firewood used and climate zone.**See warranty pg. 54 of the manual14
2. PRELIMINARY INSTALL GUIDEPreliminary Install INFORMATIONFor the installation and use of this appliance, the fitter and the user should strictly adhere to local andnational regulations as well as AS/NZS 2918:2018. They should also comply with the instructions andrecommendations detailed in this manual. Safety and operation of the fireplace is directly dependentthereon. The liability of the manufacturer can neither be retained nor assured following failure ofinstallation or incorrect use which does not comply with AS/NZS 2918:2018.As each installation is a particular case, a qualified and licensed trades professional should take allrequired preliminary precautions depending on the technical elements inherent to each job.In-observance of the assembly instructions in conjunction with AS/NZS 2918:2018 entails the liabilityof the person who carries it out.As a result of faulty assembly, irrational use of parts or additional components that were not suppliedby the manufacturer/distributor, and/or modifying of the appliance or components will result in inferioror unsafe operation. Should this occur the manufacturer/distributor bears no liability, and will result in anull and void product warranty.PLEASE READ PRIOR TO INSTALLAll images and diagrams in this manual are for installation reference purposes only and are not toscale. The distributor and manufacturer bears no accuracy of these images and accepts no liability. Thepurpose of these images and diagrams is to act as a guide in conjunction with the written componentsand are NOT to instruct independently. The order of these steps are a recommendation only.It is strongly recommended that the licensed trade professional who is performing the installation ofthis appliance, completely read and understand all instructions in this manual prior to proceeding.Sculpt Fireplaces & Axis reserves the right to change these specifications without prior notice.For reasons of quality control, some of our appliances are delivered assembled. Parts including legs andbaffle plate may need to be installed on site.EXPOSURE TO ELEMENTSAxis fireplaces are exclusively designed as indoor heating appliances, should the fireplace (or part there of) be incontact with the outside elements including rain, snow, direct sunlight, excessive winds, etc. Then the damagesustained thereon will not be covered under the manufacturer or distributor warranty. Please consider prior toinstalling your fireplace exposed to outside elements.ACCEPTABLE VARIANCE ALLOWANCEDue to the production of these hand assembled and manufactured fireplaces, there is an acceptable allowanceof 3-5mm variance of the unit, including the door frame. This variance in production is non-claimable under anywarranties.heat resistant materialsHeat resistant materials must meet AS/NZS 2918:2018 clause 1.4.27 a material with an allowable servicetemperature of 600 Celsius or greater. Gyprock Fyrecheck is NOT a recommended heat resistant material.15
2. PRELIMINARY INSTALL GUIDEIt is the users duty to make themselves aware of and apply all national or more restrictive localstandards and regulations (AS/NZS 2918:2018).IMPORTANTPrior to unpacking and installation check that the appliance has not been damaged during transport.Ensure you check the glass, the door(s), the damper operation and the door locking mechanismBefore any work is carried out, as per local and national regulations and laws, this appliance MUST beinstalled by a licensed professional as per Australian and New Zealand Standards 2918:2018.IMPORTANT WARNINGIt is strictly forbidden to use any combustible materials (ie: wooden framing, plaster, etc) near or aroundthis appliance. Any exception from this rule is a health and safety hazard which will result in a noncompliant installation and a void of warranties.Electrical cables and components must not be placed in the vicinity of the appliance as it is a firehazard.16
2. PRELIMINARY INSTALL GUIDEPLEASE READ PRIOR TO INSTALLFresh air inlet, recommended for all installationsThe air inlet is recommended for installation and is essential for the proper function of the appliance. The freshcombustion air inlet must be a minimum 300cm2 and ideally positioned (see point A & B on diagram).Air ventsFalse CeilingHot air gridNon combustible wallFireboxClearance Gap 50mmAB17
2. PRELIMINARY INSTALL GUIDEPLEASE READ PRIOR TO INSTALLleg assemblyBefore beginning any work, we remind you to check the resistance and stability of the floor where the appliance isto be installed. Installing the legs will allow you to raise the appliance by a total of 600mm.To streamline the installation we advise you to assemble the feet sets prior to beginning the leg assembly. Each setincludes a flat angle bracket and a standard angle bracket, please check these components before proceeding withassembly.ABdiagram adiagram BWe advise you to cross the nuts and boltsin order to ensure a better bearing (refer todiagram A)The standard bracket has a space withouthole which has to be turned towards the top(refer to diagram B)18
2. PRELIMINARY INSTALL GUIDEPLEASE READ PRIOR TO INSTALLOpening lower VENTS - required if APPLIANCE is to installed without legsIf you plan on installing the unit excluding the legs you MUST open ALL vents located at the bottom of the applianceprior to installation, this will ensure sufficient air flow around the unit, failure to complete this step will impactnegatively on the functionality of the appliance.To open the air vents simply apply a medium amount of pressure to the steel cover, the hatch should come free.Once completed these pieces can be discarded.air vents closedair vents open19
3. outdoor air kitPLEASE READ PRIOR TO INSTALLFLEXI FLUE for OPTIONAL OUTDOOR air kitH1200, H1200DS, H1200VLD/G, H1400, H1600, H1600 DS, H1600XXL, H1600XXLDSThe diagram pictures below details the air kit connection options for Axis appliances(H1200, H1200DS,H1200VLD/G, H1400, H1600, H1600DS, H1600XXL, H1600XXLDS), depending on your particular installationand model, your options may be limited. Carefully evaluate which options are appropriate for your installation andstructure accordingly.Double side models are only manufactured with option A for outdoor air kit connection.IF INSTALLING AN INLINE FAN WITHIN THE DUCTING TRANSFER KIT THEN AN OUTDOOR AIR KIT IS MANDATORY.AN IN LINE FAN CAN NOT BE INSTALLED ON DOUBLE SIDED UNITS.Alternative exteriorconnection portsInteriorconnection portexteriorconnection portsCCBAencfeoiaplapsBaCOVER PLATE:Please remove if applicable.OPTION aOPTION BInterior to exterior connection for outdoor airkit duct. Please note diagram A is the onlyinstallation option for double sided applianceinstallation. Remove the exterior cover plate byapplying medium pressure, once removed youcan dispose of this cover.Interior to exterior connection for outdoor air kitduct. Please note this connection option is onlyavailable on single sided appliances, double sided appliances do not have this connection port.Remove the exterior cover plate by applyingmedium pressure, once removed you can disposeof this cover.OPTION CAlternative air kit connection ports, depending onyour installation circumstance, you can alternatewhich connection ports you utilise. Remove theexterior cover plate by applying medium pressure,once removed you can dispose of this cover.20
3. outdoor air kitPLEASE READ PRIOR TO INSTALLFLEXI FLUE for OPTIONAL OUTDOOR air kitApplianceH1200 3V, EPI950**IMPORTANT**Please ensure you have attached legs beforebeginning the installation of the outdoor air kit.The diagram pictures details the air kit connection options for Axisappliances (H1200 3V and EPI950), depending on your particularinstallation and model your options may be limited. Carefullyevaluate which options are suitable for your installation.STEP 1.To access the connection ports for the air kit, first remove the ashgrate, then ash pan from the fireplace. You can access the ashgrate and pan on the base interior of the appliance.Please refer to diagram A for reference.DIAGRAM aSTEP 2.Locate the connection for the air kit port after removing the ashpan, remove the cover plate by applying medium pressure. Onceremoved you can dispose of this cover.Please refer to the diagram B for reference.STEP 3.cover plate for OUTDOOR air kit portLocate the outdoor air kit under the base of the appliance and fixinto place, depending on your particular installation allocate theexchange accordingly, see diagram C.1 for reference.Please refer to diagram C for reference.DIAGRAM BDIAGRAM C.1ApplianceDiameter: 200mmDiameter: 250mmDIAGRAM CExchange for outdoor air kit21
3. outdoor air kitStep 4.Fix outdoor air kit exchange into place, utilising accesslocated in the interior of the appliance refer to diagram E forthe correct positioning of washers and screws.Once completed connect ducting to run to exterior airconnection, ensure the exterior connection is protected by avermin proof cowl.Please refer to diagram D for referenceSTEP 5.Included with the outdoor air kit is a damper and dampercontrol, installation of this feature will assist the user in thecontrol of the air intake for the outdoor air kit. The positionof the control can be varied, we recommend assessing whichlocation is ideal for your installation, keep in mind the usershould be able to easily access this feature at all times.DIAGRAM DPlease refer to diagram F for referenceReference application for the damper control from 0%(Closed) to 100% (Fully open).Please refer to diagram F for reference.DIAGRAM EDIAGRAM F22
4. COMPONENTS LISTIMPORTANTThis components list details the amount of flue supplied (by the retailer) according to unit and minimum flue kitrequirements. For correct use please ensure you are referring to your unit model and installation kit type. For anyquestions in relation to the supplied components contact your local retailer. Each unit is supplied with a ductingkit consisting of; two metal registers and two ducts (4 Zero Type: aluminium inner core, aluminium outer, polyinsulated, minimum RI.0) by the retailer.5.4M inbuilt triple skin flue kit - axis H1200, H1200DS, H1200 VLG/VLD,H12003VQuantityCOMPONENTS6900MM Stainless flue - 250mm diameter5900mm galvanised flue - 300mm diameter5900mm galvanised flue - 350mm diameter1Wind rim cowl to suit5.4M inbuilt triple skin flue kit - axis H1400, H1600, H1600DS, H1600XXL,H1600XXLDSQuantityCOMPONENTS6900MM Stainless flue - 300mm diameter5900mm galvanised flue - 350mm diameter5900mm galvanised flue - 400mm diameter1Wind rim cowl to suit5.4M inbuilt triple skin flue kit - AXIS EPI950QuantityCOMPONENTS6900MM Stainless flue - 280mm diameter5900mm galvanised flue - 330mm diameter5900mm galvanised flue - 380mm diameter1Wind rim cowl to suitSculpt Fireplace Collection bears no liability to the functioning and supply of these components.Additional components required for installation are the responsibility of the retailer and(or) installer.23
PLEASE READ PRIOR TO INSTALLThe diagrams depicted in this manual feature the installation procedure for the Axis H1600, while thismay not be the same unit as your appliance, the process of the installation procedure across the rangeis standardised & should be adapted to suit your unit requirements. Depending on your appliance andinstallation scenario elements may vary including frame, cavity and dimensions.No two installation follows the exact same procedure, as no two homes are alike, it is importantto work with your professional installer, architect and builder to structure a custom installation thatsuits your scenario. Further questions regarding your appliance and its installation should be directedtowards your authorised dealer.All images and diagrams in this manual are for installation reference purposes only and are not toscale. The distributor and manufacturer bears no accuracy of these images and accepts no liability. Thepurpose of these images and diagrams is to act as a guide in conjunction with the written componentsand are NOT to instruct independently. The order of these steps are a recommendation only.It is strongly recommended that the licensed trade professional who is performing the installation ofthis appliance, completely read and understand all instructions in this manual prior to proceeding.Sculpt Fireplaces & Axis reserves the right to change these specifications without prior notice.IMPORTANT: For possibly replacing the flue or for a technical intervention, the installation of anaccess hatch on the fireplace cavity is highly recommended.ACCESS HATCH:24
5.1 MASONRY BRICK INSTALLATIONSTEP 1: BASELay a masonry base, minimum 100mm thick (ie. solid bricks).The base should be laid on an adequate ground supporting itsweight.STEP 2: BACK WALLUsing masonry, construct the back wall from the base to thetop of the ceiling.STEP 3: SHEET METAL LAYER (OPTIONAL STEP)Place a thin piece of sheet metal on top of the bricks in order tolevel the base and safely manoeuvre the firebox.Allow a minimum of 100mm on all sides.25
5.1 MASONRY BRICK INSTALLATIONSTEP 4: assembly of legsIf your installation requires the unit be elevated, install theappliance legs at this stage. Ensure the legs are adjusted andfixed at this stage.*IMPORTANT*Refer to appliance legs installation in the preliminary installsection.STEP 5: POSITIONING OF THE UNITPlace the firebox into position on top of the sheet metal.Remember to leave a 25mm air gap on all sides of the firebox.If the unit is to be installed without legs please refer to vents inthe preliminary install guide.*IMPORTANT*There MUST be a minimimum of 150mm clearance between thebase and the bottom of the unit.*IMPORTANT* Releasing glass doorPrior to continuing with installation ensure you release theglass door. First remove pins located on either side of the unit,then proceed to slowly lower the door from its factory position.You should now be able to open and close the door.outdoor air-kitSTEP 5A: OUTDOOR AIR KIT(OPTIONAL)externalwallconnectionto unitFLEXI FLUEVerminproofCOWLAny depression or lack of fresh air within the room where thefireplace is located can cause emanation of smoke to flowback into the room and the unit to run inefficiently. It is highlyrecommended that an Outdoor Air Kit be installed in six ormore star rated homes, or any install where a mechanicaldevice (ie. fan), takes air from the fireplace cavity & transfersit.Place the adaptor underneath the unit and feed through thebottom and attach to the internal front adaptor. Attach the flexiflue to the adaptor and run to the external brick wall at the rearof the unit, then proceed to connect the metal vermin proofcowl onto the outside wall.The flexi flue can be positioned either side of the adaptor inorder to fit between the heater and the wall. It is not requiredthat the flexi flue be positioned directly behind the firebox.*IMPORTANT*Refer to Air Kit installation in the preliminary install section.26
5.1 MASONRY BRICK INSTALLATIONSTEP 6: TRIM (OPTIONAL STEP)**IMPORTANT**Trim must be fitted onto the firebox PRIOR to installing thefront of the enclosure.1.2.3.4.5.Manoeuvre the trim on the front of the firebox.On the side of the façade of the firebox drill two holes at4.2mm.The holes must match with the slotted holes on the trimManoeuvre the trim into desired position.Fix the trim into place using the screws provided (screwsM5 washers).STEP 7: FIRST LENGTH OF FLUEPlace the first single skin length of flue (with no crimp ends)around the outside of the spigot. You may also use a heatresistance sealant (i.e.Firecork) to seal any air gaps. Prior tocontinuing with flue installation please continue to the nextstep.STEP 8: SIDE WALLSUsing masonry (ie. clay bricks) build a layer of bricks fromthe base to the top of the ceiling on either side of the firebox.Remember to leave a 25mm air gap on all sides of the unit.**IMPORTANT**If you are installing your appliance with side vents please allowfor the vent openings in the cavity exterior.Ventilation is required on the enclosure to help with aircirculation. A minimum of two air intake grills are requiredat the bottom and a minimum of two air out-take grills arerequired at the top of the masonry enclosure. All vents can bepositioned either side OR the front of the masonry enclosure.Minimum vent sizes are 100mm x 300mm with a minimum offour vents.*All air vents must must have a minimum clearance tocombustibles of 600mm in front of and 500mm above themetal vent itself.27
5.1 MASONRY BRICK INSTALLATIONSTEP 9: CAVITY LIDcavity lidto be FULLYSEALED TOALL EDGES.500mmBELOWCEILING15 **IMPORTANT**SIDE VENTSIt is highly recommended the cavity lid be installed flat to ensuresufficient air flow around the appliance if 2 vents are used.FRONT VENTSIt is highly recommended the cavity lid be installed on an angleof 15 facing the front of the fireplace to ensure sufficient airflow around the appliance.The cavity lid must be installed 500mm below the ceiling andbe comprised of the following; minimum 0.5mm thick steelplate for support, followed by a 12mm thick heat resistantsheet, with 1 x 25mm Rockwool sheet. A hole is to be cut inthe centre of the lid in order for the single skin flue to penetratethrough tightly. You may also use a heat resistance sealant (i.e.Firecork) and heat proof tape to seal any air gaps.It is important to ensure the cavity lid is fully s
aXiS notice to inStaller: these instructions must be left with the owner, who should retain for future use. 5.1 maSonry Brick inStallation 5.2 HeBel inStallation edition: 04/06/2021. 2 ComplianCe plate and serial number. . Sculpt Fireplace Collection Congratulations! 4 iMPortant